E55
This meter has an AC frequency response to 3 MHz. The TEMOD item
has a frequency response to 5 kHz. The TEMOD item shall replace the
850 for all applications below 5 kHz.
The AN/GRM -114A is intended as an enhancement item of TMDE to be
E56
used to augment standard bench equipment for field FM and avionics
radio repair. When authorized for such use, the TMDE at these bench
positions (listed with condition code E56) will remove from the field all
TMDE previously dedicated for such use and receive an AN/GRM -114A.
Note that the replacement ratio of bench positions to AN/GRM -114A's will
be 2:1; i.e., if there are four bench positions that have all or a portion of
the TMDE listed with condition code E56, two benches will remove from
the field all equipment and receive each an AN/GRM -114A; the other two
benches will not receive any AN/GRM -114A's and retain their TMDE.
Most of the TMDE retained will be replaced by other TEMOD items (see
additional condition code listed with each TMDE).
E57
Replaced by AN/USM-459 in cases other than that described in E56.
E58
Replaced by SG -1288 in cases other than that described in E56.
E59
Replaced by TS -4084/G in cases other than that described in E56.
E60
Replaced by SG -1144 or SG-1170 in cases other than that described in
E56 (also see condition codes E35, E36 and E54).
E61
Replaced by AN/USM-486 in cases other than that described in E56. Also
see condition code E8.
Replaced by AN/USM-486 in cases other than that described in E56. Also
E62
see condition code E9.
Rycom 3131 selec tive voltmeter: input impedance 75, 135, 600 and 4 k
E63
ohms; input signal level -100 to +22 dBm; selectivity filter BW = 250, 2500
Hz; rack mounted and portable versions; contains rechargeable nicad
batteries; p/o AN/TRC -90, 90A, 129, 129A, 132, 132A. Simila r to ME-
378/U. TEMOD item input impedance 75, 124, 135, 600 and 10 k ohms;
input signal level -120 to +20 dBm; selectivity filter BW = 20, 400, 3100
Hz and C-MSG weighing; not battery powered.
E64
+42 dBm (245 microV to 97.5 V); input impedance 135, 600, 2.4 k ohms,
10 k ohms 20 -pin input connector; selectivity filter BW = 100 Hz. TEMOD
item input signal level -120 to +20 dBm; input impedance 75, 124, 135,
600 and 10 k ohms; selectivity fi lter BW = 20, 400, 3100 Hz and C-MSG
weighing.
E65
Sierra 125 Frequency Selective Voltmeter Family: input impedance: 135,
600, 20 k ohms; input signal level -90 to +32 dBm; selectivity filter BW =
250, 2500 Hz; similar to ME-295/U. TEMOD item input impedance 75,
124, 135, 600, 10 k ohms; input signal level -120 to +20 dBm; selectivity
filter BW = 20, 400, 3100 Hz and C-MSG weighing.