TB 55-4920-346-34
Table 4. AC Milliamp
Meter Calibrator Indication (MA)
Test Instrument Indication (MA)
Min
Max
200
182
218
300
282
318
360
342
378
11. DC Milliamp
a. Performance Check
(2) Set the METER MODE selector to DC MILLIAMPS and METER to the INTERNAL position on the test
instrument.
(3) Set the meter calibrator (A4) output controls to amps DC position.
(4) Adjust the current controls on the meter calibrator for an indication of 100 MA on the test instrument. Meter
calibrator will indicate between 75 and 125 MA.
(5) Adjust the current controls on the meter calibrator for each test instrument indication as listed in table 5..
Meter calibrator will indicate within the limits specified.
(6) Set all power to OFF and disconnect test equipment.
b. Adjustments. No adjustments can be made.
10
Change 1