TB 9-4920-363-24
Pneumatic pressure standard indications
Test instrument indications
(knots)
(knots)
Min
Max
60
58.0
62
100
98.0
102
110
108.0
112
140
137.5
142.5
160
157.5
162.5
200
196.0
204.0
250
246.0
254.0
300
296.0
304.0
350
345.0
355.0
390
385.0
395.0
(6) Position TI controls as indicated in (a) through (e) below:
(a) Slowly adjust PRESSURE INCREASE and DECREASE control valves
until zero knots is obtained.
(b) POWER switch to OFF.
(c) PRESSURE selector control valve to OFF.
(d) PRESSURE INCREASE and DECREASE control valves to open position.
(e) AIRSPEED case leak selector valve to CLOSED.
b. Adjustments. No adjustments can be made.
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.