TB 9-4935-552-50-2
f. Without disturbing the alignment, set VIEW/DETECT control to DETECT position.
g. Taking into account the percent deviation indicated in d, the TRD shall indicate
between 1.92 and 2.08 VPP. If not, proceed to 10c(1).
h. Press HALT on test station monitor panel.
i. Deenergize and disconnect TI and B7 extender cable. Disconnect passive probe A
from radiometer A2. Do not deenergize radiometer A2.
j. Secure TI
cover. Request the
LCSS technician to
nitrogen purge and
repressurize
the TI to 3.0 1.0 psi.
k. In accordance with TB 750-25, annotate and affix DA Label 80. When the TI cannot
be adjusted within tolerance, annotate and affix DA Form 2417.
10. Adjustments
a. Focus Adjustment
(1) Set POWER switch on extender cable B7 to OFF.
Figure 6. ITS focus and alignment points.
11