TB 9-5220-216-24
(8) Repeat steps (1) through (7) above for NO GO area of TI Headspace gage.
(9) Repeat steps (1) through (7) above for the NO GO, NO FIRE and FIRE areas of the
Wear limit / Timing gages (fig. 2). All measurement readings must fall in the measured
dimension limits of table 3. If any indications of TI are not within the limits of table 3,
perform b below.
(10) If the limited fielded timing gage 13047989 (fig. 3) was furnished, repeat steps (1)
through (7) above for both the NO FIRE and FIRE areas of the gages. If any indications of
TI are not within the limits of table 3, perform b below.
Measured dimension limits
Part number
Nomenclature
in inches
13027996
HEADSPACE GAGE
13027996
GO
0.2015 -- 0.2020
13027996
NO GO
0.2030 -- 0.2035
13027994
WEAR LIMIT / TIMING GAGE
13027995
NO GO
0.2120 -- 0.2125
13027995
NO FIRE
0.1140 -- 0.1160
5351214
FIRE
0.0200 -- 0.0220
13047989
TIMING GAGE (limited fielding)
5351213
NO FIRE
0.1140 -- 0.1160
5251214
FIRE
0.0200 -- 0.0220
b. Adjustments. No adjustments can be made. Proceed to Appendix A, FRONT OF
DA FORM 3023 step (11) and NOTE for instructions.
a. Disconnect all equipment.
b. Annotate DA Form 3023 (Gage Record card) which is used in lieu of DA Label 80 in
accordance with TB 750-25. See Appendix A for instructions.
c. TI should be carefully packaged in accordance with TB 750-25 Section IX.
See