TB 9-5985-314-24
controls for +6 dBm.
NOTE
Use 15% SEARCH MODE on receiver system.
(14) Connect POINT A to POINT B (fig. 4) and establish a 0.00 dB reference on
receiver system at 2.000 GHz.
(15) Connect TI into figure 4 equipment setup as listed in (a) through (c) below:
(a) INPUT PORT 1 to POINT A.
(b) OUTPUT PORT 2 to POINT B.
(c) OUTPUT PORT 3 to 50 : termination.
(16) Record receiver system indication in OUTPUT PORT 2 column of table 7.
and record insertion loss for OUTPUT PORT 2 for remaining frequencies listed in table 7.
Insertion loss will be equal to or less than the limits listed in Appendix D.
Table 7. Insertion Loss - Output Port Tracking (2 to 18 GHz)
Receiver system indication
OUTPUT
insertion loss
OUTPUT
PORT
Test
OUTPUT
PORT 2
TRACKING
frequency
PORT 3
(GHz)
(dB)
(dB)
(dB)
2.000
2.500
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
12.500
13.000
13.500
14.000
25