TB 9-5985-314-35
(2) Connect TI as shown in figure 1 equipment setup.
Press receiver system
frequency to test frequency recorded in 12 c above.
NOTE
Use 15% SEARCH MODE on receiver system.
(3) Establish a 0.0 dB reference on receiver system.
NOTE
Ensure receiver is in measurement mode.
(4) Connect mismatches as listed in table 2 to TI DEVICE UNDER TEST port.
(5) Record receiver system indication in table 3.
(6) Repeat technique of (2) through (5) above for remaining test frequencies recorded
in 12 c above.
Mismatch1
Receiver system indications (return loss dB)2
Dc to 4
4 to 8
8 to 12.4
12.4 to 18
VSWR
GHz
GHz
GHz
GHz
Model
Manufacturer
value
Min
Max
Min
Max
Min
Max Min
Max
32.26 40.003
(2334-001-1)
Premier Microwave
1.05 +.00
26.44
---
---
---
---
40.003
-.05
or
or
greater
greater
.05
(2334-001-2)
Premier Microwave
1.20 .10
17.69
---
---
---
---
---
---
26.44
(2334-001-3)
Premier Microwave
1.50 .17
12.01
---
---
---
---
---
---
16.98
(2334-001-4)
Premier Microwave
2.00 +.22
8.43
---
---
---
---
---
---
11.04
With test report provided by Primary Lab for Secondary Reference.
1
2Receiver
system indications (return loss dB) include .02/10 dB.
3Standards limitations.
Table 3. Return Loss
Measurements (with N-Short)
Test
Mismatch
Mismatch
Mismatch
Mismatch
2334-001-1
2334-001-2
2334-001-3
2334-001-4