TB 9-6625-1914-35
(2) Position TI controls as shown in (a) through (f) below:
(a) FREQUENCY control to 200 MHz.
(c) SCAN WIDTH (red) switch to PER DIVISION.
(d) SCAN WIDTH PER DIVISION switch to 10 MHz.
(e) TUNING STABILIZER switch to OFF.
(f) FREQUENCY FINE TUNE control centered.
MHz output. If signal pip display is not within 1 division of center graticule line,
perform b below.
(4) Repeat (2) and (3) above for frequencies of 400, 600, 800, and 1000 MHz.
b. Adjustments
Packard, Model 115926001, part of service kit). NOTCH FILTER FL2 assembly (fig. 11)
must be disconnected and removed for this connection.
(2) Adjust 2ND LO ADJ (fig. 11) as necessary to obtain frequency counter
indication between 1499.9 and 1500.1 MHz (R).
(3) Disconnect frequency counter and reinstall NOTCH FILTER FL2 assembly
removed in (1) above.
(4) Set BANDWIDTH switch to 100 kHz and SCAN WIDTH PER DIVISION
switch to 20 MHz.
(5) Set IF plug-in SCAN TRIGGER switch to LINE.
(6) Adjust FREQUENCY control to 0 MHz.
35