TB 9-6625-2004-35
a. Performance Check
(1) Set FREQUENCY RANGE-MC switch to 20-55 and adjust FREQUENCY-MC
dial to 50 using TUNING knob.
(2) Set signal generator for a 50 MHz, 100 mV output.
(3) Adjust TUNING knob for a 0 indication on CARRIER SHIFT meter.
(4) Set TUNE/FINE TUNE switch to FINE TUNE and adjust TUNING knob for a
0 indication on CARRIER SHIFT meter. Record signal generator frequency indication.
(5) Adjust signal generator frequency for a -250 kHz indication on TI CARRIER
SHIFT meter. Record signal generator frequency indication.
(6) Subtract lower from higher frequency indication recorded in (4) and (5) above. If
difference is not between 225 and 275 kHz, perform b below.
(7) Adjust signal generator frequency for +250 kHz indication on TI CARRIER
SHIFT meter. Record signal generator frequency indication.
(8) Subtract lower from higher frequency indication recorded in (4) and (7) above. If
difference is not between 225 and 275 kHz, perform b below.