TB 9-6625-2076-35
Figure 1. Demodulator/ALC board A3A2
and analog board A2A2.
a. Performance Check
(1) Enter a frequency of 108.000 MHz into TI. Record exact power meter indication.
(2) Enter RF LEVELS listed in table 6 into TI. The change in power meter
indication from that recorded in (1) above will be within limits specified.
b.
Adjustments. No adjustments can be made.
Test instrument
Power meter difference indications (dBm)
RF level
Min
Max
-7
0
-2
-8
-1
-3
-10
-3
-5
-14
-7
-9
-20
-13
-15