TB 9-6625-2124-35
(12) The FREQUENCY display will indicate 2C83 and the FREQUENCY/TIME
display will indicate 0F.
(13) Adjust A8R24 (fig. 6) for multimeter indication of -20.000 V dc (R).
(14) Repeat (10) above.
(15) Press function keys and enter corresponding data on keyboard as listed in (a)
through (d) below:
↓ key, DATA ENTRY 0 BKSP.
(a)
↑ key, DATA ENTRY 0 BKSP.
(b)
↑ key, DATA ENTRY 0 BKSP.
(c)
↑ key, DATA ENTRY 0 BKSP.
(d)
(16) The FREQUENCY display will indicate 2C83 and the FREQUENCY/TIME
display will indicate F0.
(17) Adjust A8R19 (fig. 6) for multimeter indication of -26.500 V dc (R).
(18) Press ↑ key four times. The FREQUENCY display will indicate 2C87.
(19) Press function keys and enter corresponding data on keyboard as listed in (a)
through (d) below:
↑ key, DATA ENTRY 00.
(a)
↑ key, DATA ENTRY 00
(b)
↑ key, DATA ENTRY 00.
(c)
↑ key, DATA ENTRY 00.
(d)
(20) The FREQUENCY display will indicate 2C8B and the FREQUENCY/TIME
display will indicate 00.
(21) Disconnect multimeter from A8TP6 and connect to A7TP3 (fig. 8). Adjust A7R22
(fig. 8) for multimeter indication of
-3.000 V dc
(R).
(22) Press ↓ key two times. The FREQUENCY display will indicate 2C89.
(23) Press function keys and enter corresponding data on keyboard as listed in (a)
through (d) below:
↓ key, DATA ENTRY 0 BKSP.
(a)
↑ key, DATA ENTRY 0 BKSP.
(b)
↑ key, DATA ENTRY0 BKSP.
(c)
↑ key, DATA ENTRY 0 BKSP.
(d)
(24) The FREQUENCY display will indicate 2C8B and the FREQUENCY/TIME
display will indicate 0F.
(25) Adjust A7R24 (fig. 8) for multimeter indication of -19.500 V dc (R).
(26) Repeat (22) above.
(27) Press function keys and enter corresponding data on keyboard as listed in (a)
through (d) below:
(a) ↓ key, DATA ENTRY BKSP 0.
(b) ↑ key, DATA ENTRY BKSP 0.
(c) ↑key, DATA ENTRY BKSP 0.
26