11. Power Supply
NOTE
b. Adjustments.
Adjust R122 (fig. 1)
for -11 V dc
Do not perform power supply check if
all other parameters are within
12. Final Procedure.
tolerance.
a. Deenergize and disconnect
all equipment
a. Performance Check. Connect digital voltmeter
and reinstall protective cover on TI.
(A3) between collector of Q127 (fig. 1) and chassis
ground using leads (BS). If digital voltmeter does not
b. Annotate and affix
DA
Label/Form
in
indicate between -10.45 and -11.35 V dc, perform b
accordance with TB 750-23.
below.