TB 9-6625-2197-50
9. Transmitter Output Power
Level Check
a. Performance Check
(1) Connect equipment as shown in figure 8, CONNECTION A.
(2) Adjust oscilloscope controls as listed in (a) through (e) below:
(a) TIME/DIV to 10 s.
(b) TRIGGER MODE to AUTO.
(c) Press MAIN/DELAYED pushbutton to enable menu TIME REF and press
soft key to LFT.
(d) Set CH 2 INVERT to On and VOLTS/DIV to 100 mV/DIV.
(e) Press oscilloscope ERASE pushbutton then press Autostore pushbutton to
STORE.
(3) Set control box PWR switch to ON and ensure RPT and SEQ switches are in
the OFF position.
Figure 8. Transmitter power -
equipment setup.