TB 9-6625-2246-50
Test instrument range
Standard
and
Calculated values
resistor
calibrator output settings
Min
Max
No. 3
(1k)
1
mA
0.9999694
mA
1.0000306 mA
No. 2
(100)
10
mA
9.999694
mA
10.000306
mA
No. 1
(10)
100
mA
99.99534
mA
100.00466
mA
No. 6
(.1)
1
A
0.9998744
A
1.0001256 A
b. Adjustments. If not
previously completed, perform paragraphs 13 through
17
a. Performance Check
(1) Press FUNCTION/RANGE blue shift key then Reset/⇒ key.
(2) Execute ACAL AC command by pressing keys as listed in (a) through (c)
below:
(a) MENU Auto Cal.
(b) FUNCTION/RANGE Menu Scroll ⇓ until ACAL AC is displayed.
(c) NUMERIC/USER 3458 then Enter.