TB 9-6625-2259-24
(15) Press F1 M3 key and set F1 M3 display to 2.000 GHz by pressing 2 with DATA
ENTRY key and then by pressing GHz/dBm/SEC DATA ENTRY key.
(16) Press F2 M6 key and set F2 M6 display to 18.000 GHz by pressing 18 with
DATA ENTRY keys and then by pressing GHz/dBm/SEC DATA ENTRY key.
(17) Set LEVEL display to +10.0 dBm by pressing 10 with DATA ENTRY keys and
then by pressing GHz/dBm/SEC DATA ENTRY key.
(18) Adjust TRIGGER MANUAL SWEEP CONTROL for a multimeter indication
(19) Adjust INCR-DECR control for a measuring receiver FREQUENCY/LEVEL
indication of +10.0 dBm.
(20) Configure measuring receiver to measure frequency at 2 GHz and allow
measuring receiver to acquire carrier frequency.
(21) Configure measuring receiver to measure RF power.
Measuring receiver
indication will be between +8.9 and +11.1 dBm.
(22) Repeat technique of (18), (20), and (21) above for remaining multimeter
indications and measuring receiver CARRIER FREQ settings listed in table 9.
Table 9. Output Power Variations Test
Measuring receiver
frequency settings
(V dc)
(GHz)
_________1
2
3.0
3
4.0
4
5.0
5
6.0
6
7.0
7
8.0
8
9.0
9
10.0
10
11.0
11
12.0
12
13.0
13
14.0
14
15.0
15
16.0
16
17.0
17
________2
18
1Adjust
TRIGGER MANUAL SWEEP control for a multimeter
indication equal to value recorded in 7 h (11) above.
2Adjust TRIGGER MANUAL SWEEP control for a multimeter
indication equal to value recorded in 7 h (12) above.
(23) Record 10 dB attenuation (fixed) value from test report at 10 MHz and 2 GHz.
21