TB 9-6625-2323-35
(e) Output On Off to on.
(f) Modulation, FM, More, FM Modes, UnLocked Wide, Previous Menu,
Previous Menu.
(g) Mod Wave, arrow key to highlight square wave, Select, Previous Menu.
(h) Edit Dev., 1, 0, 0, MHz ms dB, Edit Dev.
(i) Edit Rate, 0, ., 4, Hz ns Adrs, Edit Rate.
(j)
On/Off to on.
(k) FM.
(20) Set spectrum analyzer Center Freq to 5, GHz.
(21) Set the spectrum analyzer Span to 5 MHz and adjust the center frequency
control to position the low carrier at the center of the display. Record the frequency reading.
(22) Adjust the center frequency counter to position the high carrier at the center of
the display. Record the frequency reading.
(23) Verify that the difference between the value recorded in (21) above and (22)
above is within the limits listed in table 16.
Spectrum analyzer indication
Test description
Min
Max
200 MHz Pk to Pk dev.
190.000 M
210.000 M
(24) Reduce outputs to minimum.
(25) Disconnect equipment setup.
b. Adjustments. No further adjustments can be made.
a. Performance Check
(1) Connect equipment as shown in figure 6 below.