TB 9-6625-2361-35
POWER ON OFF pushbutton to
ON. If
multimeter does not
indicate between 5.00 and
5.10 V dc, perform b (l) below.
(4) Connect multimeter INPUT HI to VA2 (fig. 2). If multimeter does not indicate
between 5.00 and 5.10 V dc, perform b (2) below.
b. Adjustments
(1) Adjust R6 (fig. 3) to obtain a + 5.05 V dc indication on multimeter (R).
(2) Adjust R5 (fig. 3) to obtain a + 5.05 V dc indication on multimeter (R).
a. Deenergize and disconnect all equipment and reinstall protective cover on TI.
b. Annotate and affix DA label/form in accordance with TB 750-25.