(6) Press TI keys as listed in (a) through (h) below.
(a)
Preset.
(b)
Menu Input.
(c)
Resolution < or > until menu Input CH on the display is selected.
(d)
Enter ([Input 2] selected).
(e)
Resolution < or > until menu ATT2 on the display is selected.
(f)
Enter ([Off] selected).
(g)
Return to Meas.
(h)
Resolution < > (to 0.1Hz resolution).
controls for a -19.0 dBm indication on power meter no. 1. TI will indicate within limits
(8) Repeat (7) above for remaining frequencies listed in table 4. TI will indicate
Table 4. Input 2
Sensitivity (10 MHz to 1
GHz)
Synthesized signal
Power meter
generator
no. 1
Test instrument indication limits
Frequency
Indication
Min
Max
(dBm)
10 MHz
-19.0
9999999.9
10000000.1
100 MHz
-19.0
99999999.9
100000000.1
500 MHz
-19.0
499999999.9
500000000.1
1 GHz
-19.0
999999999.9
1000000000.1
(9) Reduce all outputs to minimum and disconnect equipment setup.
b. Adjustments. None.
10. Input 1
Sensitivity Test (600 MHz to
26.5 GHz)
a. Performance Check
(2) Press TI keys as listed in (a) through (f) below:
(a)
Preset.
(b)
Menu Freq.
(c)
Resolution < or > until menu Count on the display is selected.
(d)
Enter ([Normal] selected).
(e)
Return to Meas.
(f)
Resolution < or > (to 0.1 Hz resolution).
amplitude controls for a -33 dBm indication on power meter no. 1. TI will indicate