TM 9-4935-294-15/2
counter assembly, follow the order of removal shown in
semble the A-band rf head completely, follow order of
(2) Assembly. To assemble the counter assembly,
(2) Remove diode, and replace, if required.
Note. For disassembly and assembly of the connector
Observe the following procedures:
(a) Cement counter window (23, fig.4-33) to
bracket assembly and counter assembly, refer to e and
f, respectively, below.
counter assembly (19) with type III, MILE-5092A
d. Assembly of A-Band Rf Head. To assemble the A-
adhesive.
(b) Obtain gears (16) and (17). If they are
replacements, ascertain that they are the proper parts
disassembly.
and have been inspected.
Note .Apply sealing compound 10528558 or 105-28567,
(c) Turn variable resistor R1502 (18) fully ccw.
(d) Set dials of counter assembly (19) to low end
as applicable and required, to all screws not secured
e. Disassembly and Assembly of Connector Bracket
(e) Install gear (17) on counter assembly (19)
Assembly. To disassemble and assemble the connector
shaft and engage with gear (16). Do not tighten
setscrew.
and perform all
(f) Install gear (16) on shaft of variable resistor
(18). Do not tighten setscrew.
f.
Disassembly and Assembly of the Counter
(g) Check counter setting and position of variable
Assembly.
resistor (18). Both settings must be as specified in (c)
and (d) above.
(1) Disassembly.
To disassemble the
(h) Secure gears to respective shafts with
setscrews.
Section V. REMOVAL AND INSTALLATION OF A COMBINATION CASE DRAWER AND
DISASSEMBLY AND ASSEMBLY OF COMBINATION CASE
(2) Depress locking buttons (5) of slides and slide
4-24. General
equipment drawer (2) completely out of combination
case (1).
This section contains instructions and information
(3) Release cover lock (6) and lift equipment
necessary for removal and installation of a typical drawer
drawer cover (7). The list of drawer contents (8) and an
in a combination case and for disassembly and assembly
associated component location diagram are attached to
of the combination case itself.
the front of the
drawer.
4-25. Removal and Installation of Drawer No. 1 in
b. Reinstallation. To reinstall the drawer, refer to
Combination Case No. 6
The removal and installation procedures for all drawers
are similar to those described below.
4-26. Removal and Installation of Inner Frame and
a. Removal. To remove the drawer from
Isolator Shock Mounts
a. Removal. To remove the inner frame and isolator
proceed as follows:
shock mounts from the combination case, refer to figure
(1) Depress locking buttons (3) of equipment
4-35. For disassembly and assembly of the isolator
drawer no. 1 (2) and slide equipment drawer (2) forward
shock mounts, refer to b and c, respectively, below.
until drawer slides (4) lock in full forward position.