Figure 1. Monitor, Electrical Power MX-8570/APS-94D,
controls, indicators, and connectors.
used in encouraged. Reports should be submitted on
Size.................... 19.25 H x 24.25 W x 21.13
DA Form 2028 (Recommended Changes to Publi
D inches.
cations) and forwarded direct to Commanding
Weight
58 lbs.
General, U.S. Army Electronics Command, ATN:
Reference .......................... TM 11-5995-207-12, TM 11-
AMSEL-ME-NMP-EM, Fort Monmouth, N.J., 07703.
5995-207-45
b. Specifications.
Input power requirements AC 115 Vac + 10'7. 400 Hz, 3
3. Description. The instrument described in this bul
phase, 3 amps per phase.
letin is portable special test equipment for Radar
DC 28 + 2 Vdc, 10 amps.
Surveillance Set AN/APS-94D. The instrument moni
Voltage AC phase AB&C Meters on unit under test
tors primary power supplied to the AN/APS-94D,
read AC volts within 2
when the AN/APS-94D is operated on a test bench,
percent of DVM reading.
and provides primary power overload protection.
Ampere AC phase AB&C Meters on unit under test
Additional data is listed in a through c below.
read AC amps within + 2.1
percent of Weston am-
a.
Identification.
meter reading.
Voltage DC ......................... Meter on unit under test
Nomenclature
Monitor, Electrical Power
reads DC volts within + 2
MX-8570/APS-94D
percent of DVM reading.
2