TB 11-6625 -3263-25
Condition Codes
Code
Condition
E12
The AN/USM-44, AN/USM -44A, AN/USM-44B, TS -510/U, TS-510A/U and
the TS -510B/U are various configurations of the Hewlett Packard model
608. The TS-510's are the signal generators, while the AN/USM-44's are
E36
Replaced by SG -1144 (or SG -1170, see E54) when used in all
applications other than FM radio repair. When used to repair FM radios,
the AN/GRM-114A can replace this item at bench positions designated for
the AN/GRM-114A.
These items are also on the SG-1144's replacement list. If item has not
E54
already been replaced by the SG-1144, and supplies of the SG-1144 are
depleted, replacement item is the SG-1170.
E82
The AN/GRM -50 series has an output of +22.5 dBm (3 volts) into 50 ohms.
The SG-1144 and the SG -1170 both have output voltages of +13 dBm
(1 volt) into 50 ohms; the AN/GRM -114A, 0 dBm (0.1 volts) into 50 ohms.
Where the AN/GRM-50 series is us ed to support AM radios with high
output power that require 3 volts RMS stimulus to drive audio circuitry
(such as the AN/GRC -106), units will retain the AN/GRM-50's. Units that
do not require output voltages above +13 dBm for testing end systems
such as the AN/GRM -50's with the SG-1144 or SG-1170 or
AN/GRM -114A (also see E36, E37, and E54).
E103
The SG-1170/U will replace this item for all applications except where it is
used to support testing of the AN/ARN -83. These units will retain this item.
No type designator assigned. Commercial make and model number
I1
appears in Type Designator column.
This is a TEMOD item, however, no additional procurements of SG -1144's
I6
are anticipated. Use SG-1170 as replacement (i.e., SG-1144 will not be
purged by SG-1170; additional requirements for SG-1144's will be
satisfied with SG -1170's).
P1
Item will not be removed from the field at this time; however, item is
replaceable by TEMOD item. This item will be LCC B (if type classified)
and is technically suitable for retention against authorizations for the
standard TEMOD LCC A item. (i.e., Objective is to fill shortages with
suitable item pending availability of LCC A item).
P2
Item does not have a LIN; however, item is capable of being replaced by
TEMOD item and will eventually be removed from the field by attrition. Unit
should take action to update authorization documents to include TEMOD
item.
(i.e., Objective is to get MTOE's/TDA's updated.) Following formal
authorization and requisition, the TEMOD item will be issued.
P3
Item removed fr om the field in certain applications; see applicable "E"
code/s.
4-113