TB 55-4920-428-35
Table 1. Calibration Description (Test Set Not Modified)
Test Instrument Parameters
Performance Specifications
Power Input Requirements
115 to 117 vac 50-60 Hz
DC Power Supply PS2
Range:
28.0 vdc
Accuracy:
0.5 vdc
DC Power Supply PS1
+ 12.0 vdc
Range:
Accuracy:
0.5 vdc
-12.0 vdc
Range:
Accuracy:
0.5 vdc
AC Power Supply PS3
Range;
13.0 vac
Accuracy:
0.5 vac
Range:
400 Hz
Accuracy:
5.0 Hz
Bite Terminal Voltages
Range:
5.0 vdc
Accuracy:
0.3 vdc
Range:
12.0 vdc
Accuracy:
0.5 vdc
Range:
-12.0 vdc
Accuracy:
0.5 vdc
20.0 vdc
Range:
Accuracy:
1.0 vdc
-20.0 vdc
Range:
Accuracy:
1.0 vdc
13.0 vdc
Range:
Accuracy:
0.5 vdc
.9 vdc
Range:
Bite SAS1 Self, Cross
0.1 vdc
Accuracy:
SAS2 Self, Cross Voltages
18.0 vdc or -18.0 vdc
Range:
Valve Servo Voltage
2.0 vdc
Accuracy:
-50 to +50 uadc
Range:
Nullmeters
5.0 uadc
Accuracy:
4