TB 55-4920-428-35
(e) PRESS TI SAS1 FEEDBACK SELECT to SELF.
(f) FUNCTION SELECT TO CLSD LOOP.
(42) Digital multimeter will indicate between 0.95 and 1.05 vac. Observe TI DVM for an indication be-
tween 0.95 and 1.05. Nullmeter will indicate 10 1 minor division to the right.
(43) Set TI POWER to OFF.
(44) Position TI controls (a) thru (e) as follows:
(a) SYSTEM SELECT to BITE.
(b) EXTERNAL METER SELECT SAS1 to CROSS FDBK.
(c) BITE to SAS1 CROSS.
(d) POWER to ON.
(e) PRESS TI SAS1 FEEDBACK SELECT to CROSS.
(45)
Digital multimeter will indicate between 0.95 and 1.05 vac. Observe TI DVM for an indication be-
tween 0.95 and 1.05. Nullmeter will indicate 10 1 minor division to the right.
(46) Set TI POWER to OFF.
(47) Disconnect digital multimeter leads from TI EXTERNAL METER JACKS SAS1 and reconnect to
EXTERNAL METER JACKS SAS2.
(48) Position TI controls (a) thru (f) as follows:
(a) SYSTEM SELECT to BITE.
(b) EXTERNAL METER SELECT SAS2 to SELF FDBK.
(c) BITE to SAS2 SELF.
(d) POWER to ON.
(e) PRESS TI SAS2 FEEDBACK SELECT to SELF.
(f) FUNCTION SELECT TO CLSD LOOP.
(49)
Digital multimeter will indicate between 0.95 and 1.05 vac. Observe TI DVM for an indication be-
tween 0.95 and 1.05. Null meter will indicate 10 1 minor division to the right.
(50) Set TI POWER to OFF.
Change 1 21