TB 9-6625-2089-24
Test instrument
parameters
Performance specifications
Range: 0.09 μs
Challenge sub pulse
Accuracy: 0.05 μs
Variable: <2 to >4 μs
Range: 0.25, 0.50, 0.80 and 1.70 μs
Challenge pulse width
Accuracy: 0.05 μs
Variable: <0.25 to >1.7μs
Risetime: 0.05 to 0.1 μs
Falltime: 0.05 to 0.2 μs
ISLS pulse
Range:
Spacing: (P1 to P2): 2.0 μs, 0.15 and 0.60 μs
Width:
Mode 1: 0.8 μs
Mode 4: 0.50 μs
Accuracy: 0.05 μs
Variable: <1.0 to >3.0 μs
Suppressor pulse
Range:
Amplitude: 20 V
Width: 30 μs
Accuracy:
Amplitude: 2 V
Width: 3.0 μs
Rise and fall time: 20 V/μs or greater
Mode 4 interface input
Range:
and output
Amplitude: 5.0 V
Width: 0.5 μs
Spacing: 1.8 μs
Delay between input and output: 200 μs
Accuracy:
Amplitude: 0.5 V
0.1 μs
Width:
0.1 μs
Spacing:
5.0 μs
Delay:
Mode 4 disparity
Range:
Amplitude: 5.0 V
0.5 μs
Width:
Accuracy:
Amplitude: 0.5 V
0.1 μs
Width:
65 1 μs after enable trigger or coincident
Delay:
with the pulse at 66 μs
SIF reply marker
Range:
Amplitude: 0.5 V minimum
0.15 μs
Width:
Spacing:
1st to 2d: 20.30 μs
1st to 3d: 24.65 μs
1st to 4th: 49.30 μs
Accuracy:
Amplitude: Minimum
0.05 μs
Width:
0.02 μs
Spacing:
4