TB 9-6625-2089-24
Test instrument
parameters
Performance specifications
Internal PRF frequency
Range:
and measurement meter
SIF: 10 to 10,000 pps
Mode 4: 5 to 5500 pps
Accuracy:
Dial: 10%
Meter: 10% at 1/10 meter scale
5% at FS
Timing markers
Range:
Amplitude:
1st level: 1.0 V
2d level: 1.7 V
3d level: 2.5 V into 75Ω
Accuracy:
Amplitude:
1st level: 0.2 V
2d level: 0.2 V
3d level: 0.3 V
Scope trigger
Range:
Amplitude: 5.0 V
3 μs
Width:
Risetime: <0.1 μs
Falltime: <0.5 μs
Variable delay: 0.5 to 4400 μs
Accuracy:
Amplitude: 1.0 V
2 μs
Width:
Variable delay: 10%
Auxiliary trigger
Range:
Amplitude: 20.0 V
1.0 μs
Width:
Risetime: <0.1 μs
Falltime: <0.2 μs
Accuracy:
Amplitude: 3.0 V
0.5 μs
Width
Challenge codes
Range:
Mode 1: 3.0 μs
Mode 2: 5.0 μs
Mode 3A: 8.0 μs
Mode C: 21.0 μs
6.50 μs
Test:
Mode 4A: 71 μs
Mode 4B: 70 μs
Accuracy:
Modes 1, 2, 3A, C, and test: 0.05 μs
Modes 4A and 4B: 0.07 μs
3