TB 9-6625-2327-35
Test instrument indications
Nominal
Typical test requirements
Setup #
Frequency
amplitude
34
1 kHz
0.56 Vrms
Flatness for 0 dB, Elliptical Filter
35
100
kHz
0.56 Vrms
Flatness for 0 dB, Elliptical Filter
36
1 kHz
0.56 Vrms
Flatness for 0 dB, Linear Phase Filter
37
100
kHz
0.56 Vrms
Flatness for 0 dB, Linear Phase Filter
38
1 kHz
1.7 Vrms
Flatness for +10 dB, Elliptical Filter
39
100
kHz
1.7 Vrms
Flatness for +10 dB, Elliptical Filter
40
1 kHz
5.6 Vrms
Flatness for +20 dB, Elliptical Filter
41
100
kHz
5.6 Vrms
Flatness for +20 dB, Elliptical Filter
42
1 kHz
5.6 Vrms
Flatness for +20 dB, Linear Phase Filter
43
100
kHz
5.6 Vrms
Flatness for +20 dB, Linear Phase Filter
(15) Disconnect multimeter from TI and connect power meter to TI Output.
(16) Press the BEGIN key, using the numerical keypad; adjust the displayed Meas'd
dBm level to match the power meter indication, then press the ENTER VALUE key.
Repeat this technique for each setup listed in table 17.
Test instrument indications
Typical test requirements
Setup #
Nominal amplitude
44
100
kHz
0.28 Vrms
2 dBm
Power meter reference for 0 dB range
45
200
kHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
46
500
kHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
47
1.5 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
48
5
MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
49
10.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
50
25.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
51
200
kHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
52
500
kHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
53
1.5 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
54
5
MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
55
10.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
56
25.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
57
40.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
58
50.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
59
60.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
60
65.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
61
70.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
62
75.1 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
63
79.9 MHz
0.28 Vrms
2 dBm
Flatness for 0 dB, Elliptical Filter
64
25.1 MHz
0.15 Vrms
-4 dBm
Flatness reference measurement
65
79.9 MHz
<0.15Vrms
-4 dBm
66
100
kHz
0.9 Vrms
12 dBm Power meter reference for +10 dB range
67
200
kHz
0.9 Vrms
12 dBm Flatness for +10 dB, Elliptical Filter
68
500
kHz
0.9 Vrms
12 dBm Flatness for +10 dB, Elliptical Filter
14