TB 9-6625-2330-35
(12) Set TI FUNCTION-MOD FREQ and DATA ENTRY keys to next frequency
(13) Frequency counter indication will be within limits specified in table 20 for
frequency setting of TI.
(14) Repeat (12) and (13) above for remaining frequencies listed in table 20.
Test instrument
Frequency counter
DATA ENTRY
indications
mod frequency
(Hz)
settings
Min
Max
1
kHz
.999
k
1.001
k
.100 kHz
.099
k
.101
k
.500 kHz
.499
k
.501
k
5
kHz
4.999
k
5.001
k
10
kHz
9.999
k
10.001
k
50
kHz
49.999
k
50.001
k
100
kHz
99.999
k
100.001
k
200
kHz
199999
200001
300
kHz
299999
300001
400
kHz
399999
400001
500
kHz
499999
500001
(15) Disconnect TI MODULATION IN/OUT from frequency counter A input.
b. Adjustments. No adjustments can be made.
a. Performance Check