TB 9-6625-2337-35
Table 20. VAR EMERG Codes - Continued
TI
Pulses to be
Minimum
Maximum
(s)
(s)
Test description
Settings
measured
VAR EMERG 1 - 5
----------------------------------------
1 to 5
49.20
49.40
VAR EMERG 1 - 6
----------------------------------------
1 to 6
69.50
69.70
VAR EMERG 1 - 7
----------------------------------------
1 to 7
73.85
74.05
VAR EMERG 1 - 8
----------------------------------------
1 to 8
94.15
94.35
+1 VAR EMERG 1 - 3
Use the arrow keys to highlight
1 to 3
25.50
25.80
VAR EMG:
Press ENTR to select +1
+1 VAR EMERG 1 - 4
----------------------------------------
1 to 4
45.80
46.10
+1 VAR EMERG 1 - 5
----------------------------------------
1 to 5
51.15
51.45
+1 VAR EMERG 1 - 6
----------------------------------------
1 to 6
71.45
71.75
+1 VAR EMERG 1 - 7
----------------------------------------
1 to 7
76.80
77.10
+1 VAR EMERG 1 - 8
----------------------------------------
1 to 8
97.10
97.40
-1 VAR EMERG 1 - 3
Use the arrow keys to
highlight
1 to 3
23.50
23.80
VAR EMG:
Press ENTR to select -1
-1 VAR EMERG 1 - 4
----------------------------------------
1 to 4
43.80
44.10
-1 VAR EMERG 1 - 5
----------------------------------------
1 to 5
47.15
47.45
-1 VAR EMERG 1 - 6
----------------------------------------
1 to 6
67.45
67.75
-1 VAR EMERG 1 - 7
----------------------------------------
1 to 7
70.80
71.10
-1 VAR EMERG 1 - 8
----------------------------------------
1 to 8
91.20
91.40
(19) Press TI keys as listed in (a) through (d) below:
(a)
Use the arrow keys to highlight REPLY SIGNAL: ENTR, (ID OF POS).
(b)
Use the arrow keys to highlight M1: 7777(ON).
(c)
Use the arrow keys to highlight M2: 7777(OFF).
(d)
Use the arrow keys to highlight F2: (OFF).
(20) Verify the pulse count and delta time between pulse repeats on channel 1 of
oscilloscope are within limits indicated in row 1 of table 21.
(21) Repeat technique of (19) and (20) above for remaining rows of table 21.
TI
Delta time indication
Number of
Test description
Settings
Minimum
Maximum
pulses
(s)
(s)
1ST REP ID OF POS
--------------------------------
26
24.55
24.75
Press FUNC, ↑
1ST REP ID OF POS M2
24.55
24.75
141
2, ENTR (CHALLENGES)
Use the arrow keys to
highlight M1: (OFF)
Use the arrow keys to
highlight M2: (ON)
Press FUNC, ↑
3, ENTR (1st REPLY)
Use the arrow keys to
highlight M1:7777 (OFF)
Use the arrow keys to
highlight M2:7777 (ON)
Measure delta time between first and fourteenth pulse.
1
30