TB 9-4920-358-35
(3) On radar test set, select Menu 10 and increase radar test set main output
frequency until TI REJECT lamp comes on. Decrease frequency until TI ACCEPT lamp
just lights. Record frequency.
(4) Decrease radar test set main output frequency until TI REJECT lamp comes
on, then increase frequency until TI ACCEPT lamp just lights. Record frequency.
(5) Subtract lower frequency recorded in (4) above from upper frequency recorded in
(4) above. Bandwidth will be between 6 and 8 MHz.
(6) Compute center frequency by adding the frequencies recorded in (4) and (5)
above and dividing by 2. Center frequency will be between 1089.5 and 1090.5 MHz.
b. Adjustments. No adjustments can be made.
10. Receiver Reference Code, Emergency and I/P Function
Operation
a. Performance Check
(1) Set TI SYSTEM TYPE switch to SINGLE CHANNEL.
(2) Initialize radar test set by selecting FUNCTION and ENTER. Set radar test
set INTERROGATOR menus as listed below:
(a) Menu 3 - M1 through MC REPLY CODES to 7700, RANGE DELAY to 0
s, SIF2 to OFF.
(b) Menu 4 - SIF CODE to 7700, DELAY to 3 s, TRIG SOURCE to
EXTERN+.
(c) Menu 14 - PRF to 257 PPS, 0 TRIG to INTERNAL.
(d) Menu 16 - SOURCE to LOW PWR, and RF to - 0.
(3) Select radar test set Menu 16, POWER, and ENTER to perform measurement
sequence. Press up or down arrow to stop measurement.
(4) Set TI REFERENCE CODE pushbuttons and radar test set REPLIES SIF
CODE in turn to
settings listed in
table 3, and
observe the
correct ACCEPT or
REJECT
indications as listed.
Radar test set
M2 REPLIES
REJECT or
SIF REPLY
Test instrument
ACCEPT
CODE
REFERENCE
CODE
conditions
(menu 3)
7700
1111
REJECT
1111
1111
ACCEPT
1111
2222
REJECT
2222
2222
ACCEPT
2222
3333
REJECT
3333
3333
ACCEPT
4444
3333
REJECT
4444
4444
ACCEPT