• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 8 Capacitance

Calibration Procedure For Fuel Quantity Gage Test Set Model 472090-002, Gtf-4, Tf20-1, And Tf579 Page Navigation
  13    14    15    16    17  18
img
. . .
TB 9-4920-451-24
Table 9 Resistance
Test instrument
Resistance
Standard
Megohmmeter
RANGE
indications
indications
switch
(M)1
(M)
settings
Min
Max
X1
0.7
0.63
0.77
X1
1.5
1.35
1.65
X1
2
1.8
2.2
X1
5
4.5
5.5
X1
10
9.0
11.0
X10
10
90.0
110.0
X100
10
900.0
1100.0
X1000
1
900.0
1100.0
1Subitute
resistance standards (No. 1 through No5) as required.
22. Final Procedure
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.
18