SECTION I. IDENTIFICATION AND DESCRIPTION
Table 1. Calibration Description Continued.

Calibration Procedure For Test Set, Control, Model T-36M (90000058) Page Navigation
  1  2  3    4    5    6    7  
img
TB 9-4920-460-24
Table 1. Calibration Description Continued.
Test instrument parameters
Performance specifications
POWER OUTPUT:
DIRECT CONNECT (RT port)
Frequency: 108 to 117.95 MHz
(Continued)
Range: -25 to -100 dBm
Accuracy: 2 dB
Frequency: 118 to 156 MHz
Range: -25 to -90 dBm
Accuracy: 2 dB
Frequency: 156 to 174 MHz
Range: -25 to -90 dBm
Accuracy: 2 dB
Frequency: 225 to 374.95 MHz
Range: -25 to -70 dBm
Accuracy: 2 dB
Range: -71 to -80 dBm
Accuracy: 3 dB
Frequency: 375 to 400 MHz
Range: -25 to -70 dBm
Accuracy:  3 dB
ANTENNA
Frequency: 29 to 88 MHz
Range: 0 to -70 dBm
Accuracy: 2 dB
Frequency: 108 to 118 MHz
Range: 0 to -70 dBm
Accuracy: 2.5 dB
Frequency: 118 to 156 MHz
Range: 0 to -60 dBm
Accuracy: 2.5 dB
Frequency: 156 to 174 MHz
Range: 0 to -60 dBm
Accuracy:  2.5 dB
Frequency: 225 to 334 MHz
Range: 0 to -60 dBm
Accuracy: 2 dB
Frequency: 334 to 400 MHz
Range: 0 to -40 dBm
Accuracy: 2 dB
Range: -41 to -50 dBm
Accuracy: 2.5 dB
Range: -51 to -60 dBm
Accuracy: 3 dB