TB 9-4931-523-35
TEST INSTRUMENT IDENTIFICATION
Nominal
Accuracy
Insertion loss at
Model Number
Manufacturer
(dB)
range
(dB)
0 dB (dB)
(GHz)
1
A200302
Weinschel
10
DC to 18
0.3
DC to 12.4
0.5
12.4 to 18
RLC
A2648B2
0 to 120
DC to 1
3
(MIS-10263)
Electronics
DC to 0.1
≤0.25
0.1 to 0.5
≤0.75
0.5 to 1
≤1.50
0.154
0 to 60
DC to 0.01
0.30
60 to 1203
0.355
0 to 60
0.01 to 0.1
0.705
60 to 1203
3.0
0.1 to 1
0 to 1203
AB20B
Microlab/FXR
20
DC to 4.5
0.7
DC to 3
1.0
3 to 4.5
AB30N
Microlab/FXR
30
DC to 4.5
0.7
DC to 3
1.0
3 to 4.5
1.2
AC20N
Microlab/FXR
20
DC to 3
0.6
AD06N
Microlab/FXR
6
3 to 4.5
0.8
AD10N
Microlab/FXR
10
DC to 4
≤1.2
AF117A69-342
Weinschel
0 to 69
DC to 18
0.5
1 to 9
DC to 18
1.0
10 to 19
DC to 18
1.2
20 to 29
DC to 18
1.4
30 to 39
DC to 18
1.5
40 to 49
DC to 18
1.7
50 to 59
DC to 18
1.8
60 to 69
DC to 18
0.3
AN9444-3
Arra
3
DC to 18
0.3
AN9444-6
Arra
6
DC to 18
AS1
Weinschel
See Weinschel 50-3, 50-6, 50-10, 50-20, and 210-3, 210-6, 210-10, 210-20
AS4
Weinschel
See Weinschel 50-3, 50-6, 50-10, 50-20, and 530A-3, 530A-6, 530A-10,
530A-20
AS5
Weinschel
See Weinschel 1-3, 1-6, 1-10, 1-20
AS5A
Weinschel
See Weinschel 1-3, 1-6, 1-10, 1-20
AS6
Weinschel
See Weinschel 2-3, 2-6, 2-10, 2-20
AS6A
Weinschel
See Weinschel 2-3, 2-6, 2-10, 2-20
See footnotes at end of table.