TB 9-5120-212-24
Test instrument parameters
Performance specifications
Power-Dyne:
Range: 0 to 1200 ft-lbs
Model PD 1201
Accuracy:
2% FS
Range: 0 to 2500 ft-lbs
Model PD 2501
Accuracy:
2% FS
Range: 0 to 12,000 ft-lbs1
Model PD 12003
Accuracy:
3% of reading from 4000 to 7000 ft-lbs
6% of reading throughout remainder of range
Range: 250 to 1200 ft-lbs
Model PD 1220
Accuracy:
3% of reading
Range: 250 to 1200 ft-lbs
Model PD 1220B
1% FS from 250 to 1200 ft-lbs2
Accuracy:
Consolidated Devices:
Range: 0 to 1200 ft-lbs
Models DPT-1200 and DPT-1200R
Accuracy:
2% of reading from 250 to 1200 ft-lbs
Range: 0 to 2500 ft-lbs
Models DPT-2500 and DPT-2500R
Accuracy:
2% of reading from 500 to 2500 ft-lbs
Advanced Torque:
Range: 0 to 1250 ft-lbs
1% FS from 250 to 1250 ft-lbs2
Model CTW 1200-T55
Accuracy:
Range: 0 to 7000 ft-lbs1
Model ATP 8000
1% FS2
Accuracy:
1
Checked at 5500 and 6000 ft-lbs only.
Due to standard limitation, TI checked at 2% of Full Scale only.
2
EQUIPMENT REQUIREMENTS
4. Equipment Required. Table 2 identifies the specific equipment to be used in this
calibration procedure. This equipment is issued with Secondary Transfer Calibration
Standards Set, AN/GSM-286; AN/GSM-287; or AN/GSM-440. Alternate items may be used
by the calibrating activity. The items selected must be verified to perform satisfactorily
prior to use and must bear evidence of current calibration. The equipment must meet or
exceed the minimum use specifications listed in table 2. The accuracies listed in table 2
provide a four-to-one ratio between the standard and TI. Where the four-to-one ratio
cannot be met, the actual accuracy of the equipment selected is shown in parentheses.
5. Accessories Required. The accessories listed in table 3 are issued as indicated in
paragraph 4 above and are used in this calibration procedure. When necessary, these items
may be substituted by equivalent items, unless specifically prohibited.
Table 2. Minimum Specifications of Equipment Required.
Manufacturer and model
Common name
Minimum use specifications
(part number)
FORCE/TORQUE
Range: 0.1-3.06 mV/V
HBM, Model MGCPlus (13589298)
INDICATOR
Accuracy: 0.03% indication
TORQUE CELL NO. 1
Range: 0 to 2500 ft-lbs
Lebow, Model 2351-102 Type II, Class 1
Accuracy:(0.5% of applied torque) (MIS-26485)
Range: 0 to 12,000 ft-lbs
Lebow, Model 2351-103 Type II, Class 2
Accuracy: 0.5% of applied torque
(MIS-26485)
1Part
of High Capacity Torque System, 7916833.