TB 9-6625-1356-35
a. Performance Check
NOTE
Do not perform power supply check if all other parameters are
within tolerance.
(1) Connect multimeter to CONNECTOR POINT 1 (fig. 1) and chassis ground. If
multimeter does not indicate between 29.1 and 30.9 V, perform b below.
(2) Connect multimeter to CONNECTOR POINT 2 (fig. 1) and chassis ground.
Multimeter will indicate between -24.25 and -25.75 V.
b. Adjustments.
Adjust A1R4 (fig. 1) for a 30 V
indication on
multimeter (R).
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.