(6) Adjust the dc power supply for a 9 V indication on the 3458 voltmeter. TI will
indicate within 8.66 V and 9.34 V.
(7) Set power supply output to minimum.
14. Final Procedure
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.