TB 9-6625-2004-35
NOTE
Do not perform power supply check if all other parameters are
within tolerance.
a. Performance Check. Connect multimeter INPUT HI to pin 6 of V15
(fig. 1) and
LO to
chassis ground. If
multimeter does not
indicate between 189.15 and
200.85 V
dc,
perform b below.
b. Adjustments.
Adjust VOLTS ADJ R127 (fig. 1) for a 195 V dc multimeter
indication (R).
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.
9/(10 Blank)