TB 9-6625-2197-40
CAUTION
Excess bending of CABLES (2) and (3) (fig. 4) may cause
damage to cables and cause test set malfunction.
NOTE
Slide CABLES (2) and (3) (fig. 4) part way through seals while
applying a slight pressure.
(4) Disconnect CABLES (2) and (3) (fig. 4) from card cage chassis connectors when
sufficient clearance is made.
(5) Remove upper housing from card cage chassis.
k. Install SMA male to female right angle connectors to COAXIAL CABLES (2) and (3)
NOTE
Card cage chassis connector coaxial cables (2) (fig. 4) will be
referred to as DIFF and (3) (fig. 4) will be referred to as SUM
through the rest of this procedure.
Install SMA to BNC female connections on SUM and DIFF outputs.
l.
m. Place lower housing beside card cage chassis.
n. Connect one end of power supply extender cable (part of transponder test set kit) to
lower housing P1 CABLE (8) (fig. 4) (this cable was disconnected in g (4) above) and the
other end of power supply extender cable to CONNECTOR (11) (fig. 4).
o. Arrange lower housing for best connection of P1 CABLE (10) (fig. 4) to
CONNECTOR J12 (15) (fig. 4, inset A) and reconnect CABLE (20) (fig. 4) to attenuator on
lower housing.
p. Install fully charged battery stick into TI.
q. Place lower housing on handles beside TI for easy access of test pushbuttons.
r. Arrange card cage chassis for a convenient view of display and easy access to SUM
and DIFF connections.
s. Connect equipment as shown in figure 5, CONNECTION A, and allow sufficient
time for equipment warm-up.
9