TB 9-6625-2288-35
(8) Press measuring receiver keys as listed in (a) through (c) below:
(a) Switch the measuring receiver from STBY to ON.
(b) Press the RF POWER key.
(c) Press the blue SHIFT key and the (5) key to measure output in mV.
Measuring receiver
frequency settings
voltage indications
(MHz)
Min
Max
3
95
105
5
95
105
7
95
105
10
95
105
20
95
105
50
95
105
90
95
105
100
95
105
175
95
105
200
90
110
300
90
110
350
90
110
400
90
110
1Verified
to 100 MHz for all systems codes except C00; for C00, verify to 400 MHz
(9) Measuring receiver indication will be within the limits listed in table 5.
(10) Adjust signal generator for remaining frequency settings listed in table 5.
Measuring receiver indication for remaining frequency settings will be within limits
b. Adjustments. No adjustments can be made.
NOTE
Do not perform power supply check if all other parameters are
within tolerance.
a.
Performance Check.
Connect digital multimeter positive lead to
3A1TP1 (fig. 3)
and connect negative lead to 3A1TP2 (fig. 3). If digital multimeter does not indicate
between. +14.49 and +14.51 V dc, perform b (1) below.
b. Adjustments.
Adjust 3A1R13 (fig. 3) for a
digital multimeter indication
between +14.49 and +14.51 V dc (ideal 14.50 V dc) (R).