Table 1. Calibration Description - Continued
SECTION II. EQUIPMENT REQUIREMENTS

Calibration Procedure For Transponder Test Set Model An/Upm-155 Page Navigation
  5    6    7    8    9  10  11    12    13    14    15  
img
TB 9-6625-2337-24
Table 1. Calibration Description - Continued
Test instrument
parameters
Performance specifications
1030 MHz
OUT:
Level:
15 2 dBm
Frequency:  1030 MHz 0.01%
60 MHz OUT:
Levels:
-30 to -90 dBm
Accuracy: 1 dB -30 to -79 dBm
2 dB -80 to -90 dBm
Frequency: swept 40 to 80 MHz
MAIN MOD
Amplitude: < 0.5 Vdc for full off condition
IN:
1 to 30 Vdc for full on condition
Pulse Width: 0.275 μs minimum
M
Impedance:  1 k
AIN RF I/O
1W TO 10KW:
Input:
Frequency: 960 to 1200 MHz
Power Level:
Pulsed Power:+30 dBm (1.0W)to +70 dBm (10 kW)
CW Power:  +30 dBm (1.0W) to +48.8 dBm (75 W)
Output:
Frequency:
1010 to 1110 MHz
Swept Freq:
1010 to 1050 MHz or 1070 to 1110 MHz
Power Level:
0 to -95 dBm in 1 dBm steps
Accuracy:
Fixed Frequency 1 dB
Swept Frequency 0.5 dB of fixed frequency at
center of sweep, and flatness over swept
frequency range 1 dB.
AUX RF I/O
1W TO 10KW:
Input:
Frequency:
1010 to 1110 MHz
Swept Freq:
1010 to 1050 MHz or 1070 to 1110 MHz
Power Level:
0 to -95 dBm in 1 dBm steps
Accuracy:
Fixed frequency 1 dB fixed frequency at
center of sweep, and flatness over swept
frequency range 1 dB.
LOW PWR IN
1W MAX:
Levels:
-12 to +30 dBm (1 W)
Frequency Range:
12 to 1200 MHz
MIXED VIDEO
HIGH LEVEL:
Amplitude:
+20 5 V
OUT:
Rise Time:
0.1 μs
Fall Time:
0.15 μs
1
Impedance:
75
0


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.