TB 9-6625-2337-35
(22) Press TI keys as listed in (a) through (t) below:
(a) Press FUNC, ENTR keys.
(b) Use the arrow keys to highlight GENERAL MENUS and press ENTR key.
(c) 3, ENTR (1ST REPLY).
(d) Use the arrow keys to highlight REPLY SIGNAL: ENTR, (SIF).
(e) Use the arrow keys to highlight SIF2: (ALT).
(f) Use the arrow keys to highlight M2: 0000 (ON).
(g) Use the arrow keys to highlight RANGE DELAY:.
(h) 0, ENTR (0S).
(i) Press FUNC, ↑.
(j) 4, ENTR (2ND REPLY).
(k) Use the arrow keys to highlight DELAY:.
(l) 0, ENTR (0S).
(m) Press FUNC, ↑.
(n) 5, ENTR (TIMING, VIDEO LEVELS).
(o) Use the arrow keys to highlight P3 DELAY:.
(p) 25, ENTR (25S.).
(q) Press FUNC, ↑.
(r) 14, ENTR (PRF/PRI).
(s) Use the arrow keys to highlight 0 TRIGGER:.
(t) ENTR (EXTERNAL+).
(23) Set the pulse generator to produce a 5 s wide, 5 V pulse with a period of 100 ms
in single step mode, (one pulse will be output each time the pulse generator is triggered).
(24) Manually trigger the pulse generator, and verify that the oscilloscope channel 1
displays changes from 14 pulses to 2 pulses with each trigger.
(25) Measure the delay from pulse on channel 2 to first pulse on channel 1 at each
trigger. The difference in delays will be within +/- 0.05 s.
(26) Press TI keys as listed in (a) through (l) below:
Press FUNC, ↑.
(a)
(b)
6, ENTR (VARIABLE PULSES).
(c)
Use the arrow keys to highlight VP1 DLY:.
50, ENTR (50S).
(d)
(e)
Use the arrow keys to highlight VP2:.
(f)
ENTR (ON).
(g)
Use the arrow keys to highlight VP2 PW:.
5, ENTR (5S).
(h)
(i)
Use the arrow keys to highlight VP2 DLY:.
60, ENTR (60S).
(j)
(k)
Use the arrow keys to highlight OR 1ST REPLY:.
(l)
ENTR (YES).
(27) Disconnect M4 PRE OUT from oscilloscope channel 2 and connect 0 OUT to
oscilloscope channel 2 input using a 75 Ω feedthrough termination.
31