TB 9-6695-263-35
Test instrument test points
Min
Max
A10TP7
-15.2
-14.8
A10TP5
+5.1
+5.3
A10TP4
-5.3
-5.1
A10TP6
+40.5
+42.5
b. Adjustments.
Adjust A10R24 (+15 V ADJ)
(fig. 1) for a
15.0-V dc
indication on
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.
15/(16 BLANK)