TB 9-4931-488-35
Table 10. Output Level Accuracy (Option 002)
Measuring receiver indications (dB)
Test
instrument
OUTPUT
25 MHz
512 MHz
1000 MHz
LEVEL
switch
settings
Min
Max
Min
Max
Min
Max
(dBm)
-10
-12.0
-8.0
-12.5
-7.5
-13.5
-6.5
-20
-22.0
-18.0
-22.5
-17.5
-23.5
-16.5
-30
-32.0
-28.0
-32.5
-27.5
-33.5
-26.5
-40
-42.0
-38.0
-42.5
-37.5
-43.5
-36.5
-50
-52.5
-47.5
-53.0
-47.0
-54.0
-46.0
-60
-62.5
-57.5
-63.0
-57.0
-64.0
-56.0
-70
-72.5
-67.5
-73.0
-67.0
-74.0
-66.0
-80
-82.5
-77.5
-83.0
-77.0
-84.0
-76.0
-90
-92.5
-87.5
-93.0
-87.0
-94.0
-86.0
-100
-102.5
-97.5
-103.0
-97.0
-104.0
-96.0
-110
-112.5
107.5
-113.0
-107.0
-114.0
-106.0
Table 11. Output Level Accuracy (Option 002 with 003)
Measuring receiver indications
Test
(dB)
instrument
25 and 512 MHz
1000 MHz
OUTPUT LEVEL
switch
settings
Min
Max
Min
Max
(dBm)
-10
-13.5
-7.5
-14.0
-6.0
-20
-23.5
-16.5
-24.0
-16.0
-30
-33.5
-27.5
-34.0
-26.0
-40
-43.5
-37.5
-44.0
-36.0
-50
-54.0
-47.0
-54.5
-45.5
-60
-64.0
-57.0
-64.5
-55.5
-70
-74.0
-67.0
-74.5
-65.5
-80
-84.0
-77.0
-84.5
-75.5
-90
-94.0
-87.0
-94.5
-85.5
-100
-104.0
-97.0
-104.5
-95.5
-110
-114.0
-107.0
-114.5
-105.5