TB 9-6625-2059-24
(11) Set PWR-OFF-BATT switch to BATT and slowly reduce dc power supply
voltage until TI just shuts off. If multimeter does not read between 10.9 and 11.1 V dc,
perform b (4) below.
b. Adjustments
(1) Adjust A1A22A1R41 (fig. 9) for an 18 V indication on multimeter.
(2) Adjust A1A22A1R6 (fig. 9) for a 15.4 V indication on multimeter.
(3) Adjust A1A22A1R55 (fig. 9) for a 12.05 V indication on multimeter.
(4) Adjust A1A14R22 (fig. 1) for a TI cutoff voltage of 11 V dc.
a. Deenergize and disconnect all equipment and reinstall TI protective cover.
b. Annotate and affix DA label/form in accordance with TB 750-25.