TB 9-6625-2237-24
(7) The TI BATTERY VOLTAGE FAIL indicator must be illuminated and the
PASS indicator must be off; if not perform b (1) below.
(9) Adjust dc power supply for a multimeter indication of 0.160 V dc.
(10) The TI BATTERY CURRENT FAIL indicator must be illuminated and the
PASS indicator must be off; if not perform b (2) below.
(11) Adjust dc power supply for a multimeter indication of 0.140 V dc.
(12) The TI BATTERY CURRENT PASS indicator must be illuminated and the
FAIL indicator must be off; if not perform b (2) below.
(13) Connect a jumper across the resistor on the calibration plug.
(14) The TI red SHORT CIRCUIT indicator must be illuminated.
(15) The multimeter must indicate between 250 and 400 mV dc.
(16) Set dc power supply to minimum and disconnect from TI.
b.
Adjustments
NOTE
Remove TI protective cover as required for adjustment.
(1) Adjust 2R2B (fig. 1) so both the BATTERY VOLTAGE red FAIL and the green
PASS indicators flicker randomly (R).
(2) Adjust 2R1B (fig. 1) so both the BATTERY CURRENT red FAIL and the green
PASS indicators flicker randomly (R).