Modulation:
listed in the title of each section. See table 1-1
External FM:
for cross index.
DC to 500 kHz 3O MHz
from DC to 100 Hz and
sponse.
c. Equipment Required. Each section through-
3 MHz to 200 kHz.
out this procedure has an equipment required
Internal AM.
950 to 1050 Hz.
table containing a minimum use specifications
*External AM
DC to 50 kHz.
column that applies to the item listed in the title
of each section.
Specifications for commercial models HP 8691A,
8692A, 8695A, 8696A, and 8697A are listed in
1-5. Differences Among Models
c. Calibration Program.
1-3b under specifications, and in
parentheses in
the text where different indications are to be
236.
observed. It is also to be noted that this equip-
Time required for calibration
20 hours (approximately)
ment being commercial "off the shelf" and not
manufactured to military specifications is sub-
ject to changes of any- type per any specified
1-4. General Instructions
Mock of serial numbers. If an indication received
in the performance check is other than that
specified, consult the yellow change sheets ship-
ance of this procedure, annotate DA Form 2416
ped with the commercial operation and service
in accordance with TM 38750.
manual before applying a red tag to the instru-
b. Unit Under Test. The item referred to as
ment. Use the value listed in the change if appli-
the UUT (Unit Under Test) will be the item
cable.