TB 9-4920-361-24
(3) Set ON-OFF-SIM ONLY switch to ON. Multimeter will indicate between 13
and 17 V dc.
(4) Set ON-OFF-SIM ONLY switch to OFF.
(5) Repeat technique of (1) through (4) above at unit tester switch settings and pin
connections listed in table 5. Multimeter will indicate within limits specified.
Table 5. Central Display and Signal Data
Unit tester
Multimeter indications (V dc)
Logic P/S switch settings
Pin connections
Min
Max
1
J2 Pin 3
-13.0
-17.0
1
J2 Pin 5
6.5
9.5
1
J2 Pin 6
6.5
9.5
1
J2 Pin 35
4.5
5.5
2
J3 Pin 1
13.0
17.0
2
J3 Pin 3
-13.0
-17.0
2
J3 Pin 5
6.5
9.5
2
J3 Pin 6
6.5
9.5
2
J3 Pin 35
3.5
6.5
1
J6 Pin 26
10.0
11.0
---
J6 Pin 27
-10.0
-11.0
---
J6 Pin 16
4.0
6.0
---
J6 Pin 29
4.0
6.0
---
J8 Pin 13
4.0
6.0
---
J8 Pin 16
4.0
6.0
1
J9 Pin 2
13.0
17.5
1
J9 Pin 4
-13.5
-17.5
1
J9 Pin 7
6.5
9.5
PILOTS control fully cw
J1 Pin 4
4.5
5.5
PILOTS control fully cw
AD/P test point
4.5
5.5
COPILOTS control fully cw
J4 Pin 4
4.5
5.5
COPILOTS control fully cw
AD/CP test point
4.5
5.5
IL/S test point
4.5
5.5
P/S Control to Remote and
variable P/S Control fully
CW (connect jumper
between J3-26 and J3-27)
(7) Connect multimeter positive to J3 pin 93 and negative to J3 pin 26 (jumper
should still be connected between J3-26 and J3-27).
(8) Set ON-OFF-SIM ONLY switch to ON. Multimeter will indicate between 7.5
and 12.5 V ac.
(9) Set ON-OFF-SIM ONLY switch to OFF.
b. Adjustments. No adjustments can be made.
CHANGE 1 17