TB 9-5120-204-24
IDENTIFICATION AND DESCRIPTION
1. Test Instrument Identification.
This bulletin provides instructions for the
calibration of Torque Wrench Weinschel, Model 2098-5065. The manufacturer's manual
was used as the prime data source in compiling these instructions. The equipment being
calibrated will be referred to as the TI (test instrument) throughout this bulletin.
a. Model Variations. None
b. Time and Technique. The time required for this calibration is approximately 1
hour, using the physical technique.
2. Forms, Records, and Reports.
a. Forms, records, and reports required for calibration personnel at all levels are
prescribed by TB 750-25.
b. Adjustments to be reported are designated (R) at the end of the sentence in which
they appear. When adjustments are in tables the (R) follows the designated adjustment.
Report only those adjustments made and designated with (R).
3. Calibration Description. TI parameters and performance specifications which
pertain to this calibration are listed in table 1.
Test instrument parameters
Performance specifications
Range: 7 to 10 in-lbs
Accuracy: r 4%
EQUIPMENT REQUIREMENTS
4. Equipment Required. Table 2 identifies the specific equipment to be used in this
calibration procedure. This equipment is issued as a calibration standard non-set
configuration. Alternate items may be used by the calibrating activity. The items selected
must be verified to perform satisfactorily prior to use and must bear evidence of current
calibration. The equipment must meet or exceed the minimum use specifications listed in
table 2. The accuracies listed in table 2 provide a four-to-one ratio between the standard
and TI. Where the four-to-one ratio cannot be met, the actual accuracy of the equipment
selected is shown in parenthesis.
5. Accessories Required. The accessories required for this calibration are common
usage accessories, issued as indicated in paragraph 4 above, and are not listed in this
calibration procedure.