TB 9-6625-1914-35
NOTE
Perform measuring receiver sensor zero and calibration prior to
making measurements in this paragraph.
a. Performance Check
(1) Connect measuring receiver sensor to TI CAL OUTPUT connector.
(2) Press measuring receiver FREQ pushbutton to acquire 30 MHz TI cal output signal.
(3) Press measuring receiver yellow S key then RF POWER key. Both keys should be lit.
(4) If power meter indication is not between -29.7 and -30.3 dBm, perform b below.
b. Adjustments
(1) Connect TI to extender (supplied with TI) and connect extender to display section.
(2) Adjust A6R54 (fig. 2 and fig. 3) for a 30 dBm 0.3 dB indication on measuring
receiver (R).
Figure 2. Model 8552A adjustment locations -
bottom view.
11