TB 9-6625-2059-35
Table 2. Minimum Specifications of Equipment Required - Continued
Manufacturer and model
Common name
Minimum use specifications
(part number)
CALIBRATOR
Range:
0.095 to 315 V ac
Fluke, Model 5720A (5700A/EP)
Accuracy: 1.25%
(p/o MIS-35947); w/ amplifier,
Range:
0.097 to 309 V dc
Fluke 5725A/AR (5725A/AR)
Accuracy: 0.75%
Range: 1 MHz to 1 GHz
Fluke, Model PM6681/656
Accuracy:0.0000125%
(PM6681/656)
Range: 999.9 to 20002 Hz
Accuracy:0.0025%
MEASURING RECEIVER
Range:
1.8 to 10.3 kHz
Hewlett-Packard, Model 8902A
Accuracy: 1.75%
w/sensors, Hewlett-Packard, Model
Measurement range: 0 to 90 dBm
11722A (11722A) and 11792A
Accuracy: 0.625 dB
(11792A), and microwave
converter, model 11793A (11793A)
Hewlett-Packard, Model 3458A
MULTIMETER
Range:
0 to 16.75 V dc
Accuracy: 0.16%
(3458A)
Range:
0.054 to 3.5 V ac
Accuracy: 1.25%
0 to 600 Ω
Range:
Accuracy: 2.5%
Range:
0.4 V p-p
Tektronix, Type 2465B-46
Accuracy: 3%
(2465B-46)
Range:
50 mV to 50 V p-p at 1 kHz
Fluke, Model 5820A-5C-GHZ
CALIBRATOR
sine wave
(5820A-5C-GHZ)
Accuracy: 1.25%
10 s to 1 ms markers
Range:
Accuracy: 0.5%
Range:
1 V p-p square wave
POWER METER
Range:
10 to -10 dBm at 10 MHz to 1 Hewlett-Packard, Model E12-432A
GHz
(MIS-30525) w/thermistor mount,
Accuracy: 2.5%
Hewlett-Packard, Model H75-478A
(7915907) or 8478B (8478B)
POWER SUPPLY
Range:
0 to 12 V
Kepco, Model HB525M20480
(7915935)
28.5 to 315 kΩ
Range:
Biddle-Gray, Model 71-631
Accuracy: 1.25%
(7910328)
Range:
100 KHz to 900 MHz
(SG1207/U)
Amplitude: 0 to -30 dBm
Range:
60% MOD at 1 kHz
SPECTRUM ANALYZER
Range:
120 to 900 MHz
(AN/USM-489A)
STEP ATTENUATOR
Hewlett-Packard, Model 355D
(355D)
Range: 30 to 600 MHz
Bird, Model 4421 (4421), w/ sensor,
Accuracy: 3%
Bird, Model 4022 (4022)
Common name
Description (part number)
150 Ω Winslow, Model 336 (7907234)
DECADE RESISTOR
LOW PASS FILTER
Telonic, Model TLC700-6EF1
LOW PASS FILTER
Telonic, Model TLC125
LOW PASS FILTER
Telonic, Model TLC45-4EF
PROBE1
1Do
not use probe AV-5388 supplied with some multimeters MM-100E.