High Frequency Compensation
Delay Dial Timing

Calibration Procedure For Oscilloscope, Types 453, 453A, 454, 454Mod163D, And 468 Page Navigation
  5    6    7    8    9  10  11    12    13    14    15  
img
. . . . .
TB 9-6625-2083-24
C328
Figure 3. Test instrument - left side view.
(6) Adjust L143A, C143A, C143C, and R143C (fig. 1 for Type 453) R143C, C143C,
C143A, and L143A (fig. 2 for Type 453A) for optimum square wave indication on TI (R).
11. Delay Dial Timing
a. Performance Check
(1) Position controls as listed in (a) through (i) below:
CH 1 VOLTS/DIV switch to .5.
(a)
A TIME/DIV switch to 1 ms.
(b)
B TIME/DIV AND DELAY TIME switch to 5 s.
(c)
HORIZ DISPLAY to A INTEN DURING B.
(d)
MODE switch to CH 1.
(e)
Set DELAY TIME MULTIPLIER dial to 1.00.
(f)
B SWEEP MODE switch to B STARTS AFTER DELAY TIME.
(g)
MAG switch to OFF.
(h)